meta data for this page
  •  

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
drives:nec_fd1157c [2022/02/11 14:43] – Added section headers; added Basic Disassembly section flandrives:nec_fd1157c [2022/02/12 10:54] (current) – [Basic Disassembly] Added warning and wordsmithing. flan
Line 45: Line 45:
  
 note: Drive 2 and controller are on one the same side of the twist, and drive 1 is on the other side. Both drive 1 (A:) and drive 2 (B:) have DX=1. note: Drive 2 and controller are on one the same side of the twist, and drive 1 is on the other side. Both drive 1 (A:) and drive 2 (B:) have DX=1.
 +
 +=== Jumper setting options ===
 +
 +(* is the default setting.)
 +
 +^ Head Load Condition      ^  HS  ^  USE  |
 +| Drive select & head load |  1       |
 +| Drive select              1       |
 +| Head load                |  2       |
 +| Drive select & motor on  |  1       |
 +| Motor on                  2     3*  |
 +
 +^ Motor On Condition ^  MON  |
 +| Drive select           |
 +| Head load          |     |
 +| Motor on             1*  |
 +
 +^ Display Lamp Condition    IUS  ^  USC  ^    LED    |
 +| Head load                |          1 and 4  |
 +| Head load & Drive select |          1 and 5  |
 +| Drive select                        2 and 4  |
 +| Ready                    |            3 and 4  |
 +| Ready & Drive select                3 and 5  |
 +| Drive select                        2 and 5  |
 +| Head load                |          1 and 4  |
 +| Head load & Drive select |          1 and 5*  |
 +
 +Note: "-" indicates that the jumper position doesn't matter.
 +
 +^ Density Switching ^|||
 +^ Record density ^ High/Normal density signal ^  DEN  |
 +| High           | H level                    |   1*  |
 +| Normal         | L level                    | :::   |
 +||||
 +| Normal         | H level                    |     |
 +| High           | L level                    | :::   |
 +||||
 +| High           | H level                    |     |
 +| High           | L level                    | :::   |
 +||||
 +| High           | H level                    |   Open  |
 +| Normal         | L level                    | :::     |
 +
 +^ Rotation Change ||
 +^ Rotation in normal density mode ^  HDE   |
 +| 360 rpm ("single speed mode"    1*   |
 +| 300 rpm ("dual speed mode"         |
 +
 +Note: A rotation in a high-density mode is 360 rpm for both short plug and "HED"=1 and 2.[sic]
 +
 +^ Disk Change/Ready ||
 +^ Disk change/ready signal output condition ^  DCG  |
 +| Ready signal                              |     |
 +| Disk change signal                        |   2*  |
  
 ==== Basic Disassembly ==== ==== Basic Disassembly ====
  
-With the drive flat on a table, with door facing you, remove the screw on the right about midway down the chassis. This screw holds the RF shielding on. With the screw out, the shielding should slide forward towards the drive door, and then lift the back up. This should allow you remove the shielding entirely. Reverse the process to put it back.+⚠️ **Use a J1 screwdriver or you will strip the screws!** Screws on this drive are type J1 JIS screws. [[https://chapmanmfg.com/blogs/news/phillips-bits-vs-jis-bits-whats-the-difference|These are similar to Phillips screws, but not the same.]]  
 + 
 +With the drive flat on a table, with door facing you, remove the screw on the right about midway down the chassis. This screw holds the RF shielding on. With the screw out, the shielding should slide forward towards the drive door. Lift the back up. You should be able to remove the shielding entirely. Reverse the process to put it back.
  
 ==== Extras ==== ==== Extras ====